Manifold
Detaches from base for quick separator interval replacement
Condensate Inlet Hub
Replace red and black caps with push-to-connect fittings (finger tighten ONLY) and insert compressor lines
Carbon-filtered Vent
Pressure is decompressed and vented through two replaceable carbon-filled cartridges, removing VOCs and reducing any oily mist expelled from the manifold
Timer Drain
Sends a burst of air through the unit every 12 hours to prevent the formation of a sludge mat. Flashing LEDs and audible sound to alert unit replacement.
Antimicrobial Cavity
Insert an antimicrobial pouch to sanitize the discharge hose and prevent algae growth
Outlet
10 ppm or less of filtered condensate exits to sanitary or floor drain
Compression-fit manifold for precise filtration control
Timer drain for improved flow of condensate through the media bed
Antimicrobial sanitization of discharge hose to prevent algae growth
Twelve available inlets (increased from six)
No maintenance or messy bag change-outs
System monitoring services and cradle-to-grave warranty

CRP 500 2000
CRP-PAKs provide a convenient and cost-effective method to keep your compressor room EPA-compliant. The innovative CRP-PAK is maintenance-free and mold resistant.
The CRP-PAKs are our most advanced line of Oil-Water Separators. These feature several upgrades to the previous generation of the IDC series. The base unit is still the same as the IDC, but the CRP-PAKs include an external manifold that is compression fit to the container and now accepts 12 inlet lines, six more than previous systemssix ¼″ and six ½″.
Built into the manifold is a pre-plumbed timer drain that generates a burst of air every twelve hours to improve the free flow of condensate through the alumina silicate substrate media bed.
CRP-PAKs also feature a discharge hub redesigned to include an antimicrobial pouch to sanitize the discharge fluid. This addition inhibits mold and algae growth, keeping the discharge hose clean and free from flow restrictions.
The manifold can be easily removed from the spent container and reattached to new containers with fresh media beds. All registered units qualify for free recycling, or the units can be disposed of as non-hazardous special waste in accordance with state and local regulations. To recycle, enter the unit serial number and fill in the form at recycleoilsep.com.

CRP 500
The CRP-500 is designed for systems from 30 HP to 250 HP.
Part Number (full system with manifold): F10501
Part Number (replacement drum only): F10501R
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
500 | 16 | 15 | 48 | 110 |
*Height includes manifold. Height without manifold: 39 in
**shipping weight
HP | ACFM | Unit Life in Hours†‡ | Est. Hrs/Yr |
---|---|---|---|
30 | 150 | 32,000 | 8,000 |
40 | 200 | 24,000 | 8,000 |
50 | 250 | 19,000 | 8,000 |
60 | 300 | 16,000 | 8,000 |
75 | 375 | 13,000 | 8,000 |
100 | 500 | 11,000 | 8,000 |
125 | 600 | 8,000 | 8,000 |
150 | 750 | 6,000 | 8,000 |
200 | 1000 | 5,000 | 8,000 |
250 | 1250 | 4,000 | 8,000 |
† Unit life numbers in this chart assume rotary screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Unit life may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor. For use with reciprocating compressors, consult factory to calculate unit life.
ROTARY SCREW COMPRESSORS (2 ppm carryover)
Unit Life: [hours from above] x [CF from below]
Example 1: CRP 1000 with 200 hp running 6,000 hrs/yr
Unit Life: 8,000 x 1.33 = 10,640 hours‡
Example 2: CRP 1500 with 150 hp running 8,000 hrs/yr
Unit Life: 24,000 x 1 = 24,000 hours‡
‡ To calculate unit life in months: [Unit Life] / 8,000 * 12
Hrs/yr runtime | 8,000 | 6,000 | 4,000 | 2,000 |
---|---|---|---|---|
Life Correction Factor (CF) | 1 | 1.33 | 2 | 4 |
Sizes and Specifications | |
---|---|
Inlets | Six ½″, Six ¼″ |
Maximum inlet pressure | 175 psi |
Timer drain power requirements | 120 Volt, 20 Amp |
Timer drain in/out poly tube | ¼″ |
Discharge hose | ¾″ |
Outlet hub cap | 3½″ |

CRP 750
The CRP-750 is designed for systems from 40 HP to 300 HP.
Part Number (full system with manifold): F10502
Part Number (replacement drum only): F10502R
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
750 | 16 | 15 | 48 | 125 |
*Height includes manifold. Height without manifold: 39 in
**shipping weight
HP | ACFM | Unit Life in Hours†‡ | Est. Hrs/Yr |
---|---|---|---|
40 | 200 | 32,000 | 8,000 |
50 | 250 | 25,000 | 8,000 |
60 | 300 | 21,000 | 8,000 |
75 | 375 | 17,000 | 8,000 |
100 | 500 | 13,000 | 8,000 |
125 | 600 | 11,000 | 8,000 |
150 | 750 | 8,000 | 8,000 |
200 | 1000 | 6,000 | 8,000 |
250 | 1250 | 5,000 | 8,000 |
300 | 1500 | 4,000 | 8,000 |
† Unit life numbers in this chart assume rotary screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Unit life may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor. For use with reciprocating compressors, consult factory to calculate unit life.
ROTARY SCREW COMPRESSORS (2 ppm carryover)
Unit Life: [hours from above] x [CF from below]
Example 1: CRP 1000 with 200 hp running 6,000 hrs/yr
Unit Life: 8,000 x 1.33 = 10,640 hours‡
Example 2: CRP 1500 with 150 hp running 8,000 hrs/yr
Unit Life: 24,000 x 1 = 24,000 hours‡
‡ To calculate unit life in months: [Unit Life] / 8,000 * 12
Hrs/yr runtime | 8,000 | 6,000 | 4,000 | 2,000 |
---|---|---|---|---|
Life Correction Factor (CF) | 1 | 1.33 | 2 | 4 |
Sizes and Specifications | |
---|---|
Inlets | Six ½″, Six ¼″ |
Maximum inlet pressure | 175 psi |
Timer drain power requirements | 120 Volt, 20 Amp |
Timer drain in/out poly tube | ¼″ |
Discharge hose | ¾″ |
Outlet hub cap | 3½″ |

CRP 1000
The CRP-1000 is designed for systems from 50 HP to 400 HP.
Part Number (full system with manifold): F10503
Part Number (replacement drum only): F10503R
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
1000 | 16 | 15 | 48 | 150 |
*Height includes manifold. Height without manifold: 39 in
**shipping weight
HP | ACFM | Unit Life in Hours†‡ | Est. Hrs/Yr |
---|---|---|---|
50 | 250 | 32,000 | 8,000 |
60 | 300 | 26,000 | 8,000 |
75 | 375 | 21,000 | 8,000 |
100 | 500 | 16,000 | 8,000 |
125 | 600 | 13,000 | 8,000 |
150 | 750 | 11,000 | 8,000 |
200 | 1000 | 8,000 | 8,000 |
250 | 1250 | 6,000 | 8,000 |
300 | 1500 | 5,000 | 8,000 |
350 | 1750 | 4,000 | 8,000 |
† Unit life numbers in this chart assume rotary screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Unit life may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor. For use with reciprocating compressors, consult factory to calculate unit life.
ROTARY SCREW COMPRESSORS (2 ppm carryover)
Unit Life: [hours from above] x [CF from below]
Example 1: CRP 1000 with 200 hp running 6,000 hrs/yr
Unit Life: 8,000 x 1.33 = 10,640 hours‡
Example 2: CRP 1500 with 150 hp running 8,000 hrs/yr
Unit Life: 24,000 x 1 = 24,000 hours‡
‡ To calculate unit life in months: [Unit Life] / 8,000 * 12
Hrs/yr runtime | 8,000 | 6,000 | 4,000 | 2,000 |
---|---|---|---|---|
Life Correction Factor (CF) | 1 | 1.33 | 2 | 4 |
Sizes and Specifications | |
---|---|
Inlets | Six ½″, Six ¼″ |
Maximum inlet pressure | 175 psi |
Timer drain power requirements | 120 Volt, 20 Amp |
Timer drain in/out poly tube | ¼″ |
Discharge hose | ¾″ |
Outlet hub cap | 3½″ |

CRP 1500
The CRP-1500 is optimized for systems from 125 HP to 600 HP but can be used with systems up to 2,000 HP.
Part Number (full system with manifold): F10504
Part Number (replacement drum only): F10504R
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
1500 | 22 | 20 | 57 | 310 |
*Height includes manifold. Height without manifold: 48 in
**shipping weight
HP | ACFM | Unit Life in Hours†‡ | Est. Hrs/Yr |
---|---|---|---|
125 | 600 | 30,000 | 8,000 |
150 | 750 | 24,000 | 8,000 |
200 | 1000 | 18,000 | 8,000 |
250 | 1250 | 15,000 | 8,000 |
300 | 1500 | 11,000 | 8,000 |
350 | 1750 | 10,000 | 8,000 |
400 | 2000 | 8,000 | 8,000 |
450 | 2250 | 8,000 | 8,000 |
500 | 2500 | 7,000 | 8,000 |
600 | 3000 | 6,000 | 8,000 |
† Unit life numbers in this chart assume rotary screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Unit life may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor. For use with reciprocating compressors, consult factory to calculate unit life.
ROTARY SCREW COMPRESSORS (2 ppm carryover)
Unit Life: [hours from above] x [CF from below]
Example 1: CRP 1000 with 200 hp running 6,000 hrs/yr
Unit Life: 8,000 x 1.33 = 10,640 hours‡
Example 2: CRP 1500 with 150 hp running 8,000 hrs/yr
Unit Life: 24,000 x 1 = 24,000 hours‡
‡ To calculate unit life in months: [Unit Life] / 8,000 * 12
Hrs/yr runtime | 8,000 | 6,000 | 4,000 | 2,000 |
---|---|---|---|---|
Life Correction Factor (CF) | 1 | 1.33 | 2 | 4 |
Sizes and Specifications | |
---|---|
Inlets | Six ½″, Six ¼″ |
Maximum inlet pressure | 175 psi |
Timer drain power requirements | 120 Volt, 20 Amp |
Timer drain in/out poly tube | ¼″ |
Discharge hose | ¾″ |
Outlet hub cap | 3½″ |

CRP 2000
The CRP-2000 is optimized for systems from 150 HP to 800 HP but can be used with systems up to 2,000 HP.
Part Number (full system with manifold): F10505
Part Number (replacement drum only): F10505R
CRP Unit | Width (in) | Depth (in) | Height (in)* | Weight (lbs)** |
---|---|---|---|---|
2000 | 22 | 20 | 57 | 370 |
*Height includes manifold. Height without manifold: 48 in
**shipping weight
HP | ACFM | Unit Life in Hours†‡ | Est. Hrs/Yr |
---|---|---|---|
150 | 750 | 30,000 | 8,000 |
200 | 1000 | 22,000 | 8,000 |
250 | 1250 | 18,000 | 8,000 |
300 | 1500 | 14,000 | 8,000 |
350 | 1750 | 12,000 | 8,000 |
400 | 2000 | 10,000 | 8,000 |
450 | 2250 | 9,000 | 8,000 |
500 | 2500 | 9,000 | 8,000 |
600 | 3000 | 7,000 | 8,000 |
† Unit life numbers in this chart assume rotary screw compressors with 2 ppm oil carryover running 8,000 hrs/yr. Unit life may vary due to differences in air compressor oil consumption rates, age, and maintenance of compressor. For use with reciprocating compressors, consult factory to calculate unit life.
ROTARY SCREW COMPRESSORS (2 ppm carryover)
Unit Life: [hours from above] x [CF from below]
Example 1: CRP 1000 with 200 hp running 6,000 hrs/yr
Unit Life: 8,000 x 1.33 = 10,640 hours‡
Example 2: CRP 1500 with 150 hp running 8,000 hrs/yr
Unit Life: 24,000 x 1 = 24,000 hours‡
‡ To calculate unit life in months: [Unit Life] / 8,000 * 12
Hrs/yr runtime | 8,000 | 6,000 | 4,000 | 2,000 |
---|---|---|---|---|
Life Correction Factor (CF) | 1 | 1.33 | 2 | 4 |
Sizes and Specifications | |
---|---|
Inlets | Six ½″, Six ¼″ |
Maximum inlet pressure | 175 psi |
Timer drain power requirements | 120 Volt, 20 Amp |
Timer drain in/out poly tube | ¼″ |
Discharge hose | ¾″ |
Outlet hub cap | 3½″ |